Smart Manufacturing. Driven by Agility, Defined by Quality.

Windform Composites Demonstrate High Electrical Insulation Performance

March 21, 2024

Windform GT, LX 3.0, and FR2 Glass fiber reinforced composites exhibit remarkable electrical insulation properties. With a dielectric constant of 4 and withstand of 2.5 kV/mm, they are ideal for demanding electrical applications, including automotive, power, and telecommunications sectors.

Elevated Electrical Insulation Performance guaranteed

Renowned for their outstanding mechanical and thermal properties, Windform composites have successfully undergone dielectric constant and dielectric strength tests. These tests are crucial for assessing the electrical performance of materials, especially when used in applications requiring electrical insulation. For instance, in modern automotive applications characterized by hybrid or fully electric vehicles, the use of insulating plastic materials is extremely important, as the entire propulsion system relies on electricity.

DIELECTRIC CONSTANT TEST

The dielectric constant, often denoted by the symbol ε₀ (epsilon zero), is a fundamental constant in physics that represents a material’s ability to resist the formation of an electric field within it.

During the test, the Glass fiber-reinforced Windform composites Windform LX 3.0, Windform GT and Windform FR2 exhibited a dielectric constant of approximately 4: Windform LX 3.0 and FR2 are slightly above 4, while Windform GT is slightly below.

The test was conducted at the standard frequency of 1 kHz.

DIELECTRIC STRENGTH TEST

The dielectric strength test was performed to evaluate the maximum electric potential difference that Glass fiber reinforced Windform materials can withstand before conducting electricity. The results were remarkable: Windform LX 3.0, Windform GT, and Windform FR2 demonstrated the ability to withstand peak voltages of at least 2.5 kV/mm without showing any signs of deterioration.

Specimens of Windform LX 3.0, Windform GT and Windform FR2, with a thickness of approximately 1.6 mm, were subjected to sinusoidal voltages alternating at 50 Hz and amplitudes up to 4000 V without ever inducing discharge. This indicates that the dielectric strength peak of these materials exceeds 2500 V/mm (4000 V / 1.6 mm = 2500 V/mm).

The results of the dielectric constant and dielectric strength tests on Glass fiber-reinforced Windform composites are of paramount importance in electrical applications. The ability of these materials to maintain a dielectric constant of approximately 4 makes them particularly suitable for electrical and electronic devices requiring high electrical insulation.

In fully electric vehicles with high voltage, the use of insulating plastic materials is essential to ensure safety, efficiency and proper operation of the electrical system. Here are some examples of where insulating plastic materials are used in these vehicles:

Battery housings. High-voltage batteries are one of the main components of electric vehicles. Battery housings can be made of insulating plastic materials that must ensure the safety and electrical insulation of the battery cells, also protecting against short circuits and mechanical damage.

Power converter housings. Power converters convert electrical energy between forms useful for vehicle operation. Power converter housings can also be made of insulating plastic materials to ensure safety and electrical insulation.

Cooling and air conditioning system components. In high-voltage electric vehicles, cooling and air conditioning systems are essential to ensure that electrical components and batteries remain at optimal operating temperatures. Cooling system components, such as ducts and tanks, can be made of insulating plastic materials to ensure electrical insulation and resistance to high temperatures.

Charging connector housings. In electric vehicles, charging connectors are essential for battery charging. Charging connector housings are often made of insulating plastic materials to ensure a safe and secure connection during the charging process.

Similarly, the ability of Glass fiber-reinforced Windform composites to withstand voltages of at least 2.5 kV/mm ensures excellent reliability and safety in environments and applications with high electrical voltages, such as in the electric power and telecommunications sectors.

These results clearly indicate that Windform thermoplastic composites are an excellent choice for applications requiring high-quality electrical performance and reliability in demanding environments.